Skip to main content
Local Warehouse Fast Dispatch3–7 Working Days DDP DeliveryFree Customization Support

JK BMS · 2A+ · High-Current Board Series

600 A Board BMS for Heavy-Duty Traction & AGV

Heavy-duty board BMS for high-dynamic-load traction: 600 A continuous, 2 A active balancing, CAN/RS485/Bluetooth for 8S–24S LiFePO4 packs in forklift, AGV, aerial work platforms, and light EV.

600 A Continuous2 A Active BalancingCAN/RS485/Bluetooth8S–24S LiFePO4

Snapshot

Cell Config

8S – 24S

Balancing

2 A Active

Continuous Current

600 A

Communication

CAN / RS485 / BT

Overview

The High-Current Series

Purpose-built for traction applications where sustained high current, motor inrush events, and vibration-resistant packaging are non-negotiable. 600 A continuous with 2 A active balancing across 8S–24S LiFePO4 configurations, with CAN bus integration tailored for forklift, AGV, and EV motor controllers.

Situation

Your team is building a traction battery pack for forklift, AGV, or light EV applications and needs a BMS that handles sustained 600 A discharge, survives motor inrush surges up to 1800 A, and talks to the traction motor controller over CAN – all within the vehicle battery compartment.

The Challenge

Standard 100–200 A BMS units trip on overcurrent during normal traction duty or need bulky external contactors that do not fit the compartment. Without proper CAN integration, the BMS cannot coordinate protection with the motor controller, leading to nuisance shutdowns and reduced vehicle uptime.

How do you find a 600 A BMS for heavy-duty traction applications with active balancing, CAN bus integration, and vibration-resistant packaging?

Our Answer

SSLBATT High-Current Series BMS delivers 600 A continuous with 1800 A peak surge, 2 A active balancing, and CAN 2.0B (J1939-compatible) communication for direct traction controller integration. The reinforced MOSFET bank, high-current busbars, and vibration-rated assembly suit 8S–24S LiFePO4 packs in forklift, AGV, aerial work platforms, and light EV – with factory parameter alignment before sampling.

Traction-Grade Power Handling

600 A continuous with 1800 A peak surge for 3 seconds handles motor inrush events that trip standard BMS units. Reinforced MOSFET bank and busbars distribute heat evenly under sustained load.

Motor Controller Integration

CAN 2.0B with J1939-compatible protocol maps SOC, voltage, current, temperature, and fault status to the vehicle ECU. RS485 and Bluetooth cover telemetry and diagnostics.

Vibration-Resistant Packaging

Board form factor with vibration-rated mounting, reinforced connectors, and conformal coating against dust, moisture, and mechanical shock in traction environments.

Where It Fits Best

View specifications
ApplicationWhy it fits
Forklift & Material HandlingSustained 600 A discharge handles lift motor demand and fast-charge cycles.
AGV & Mobile RoboticsCompact footprint with CAN integration for automated vehicle control systems.
EV Traction & LSEVMotor inrush tolerance and vibration-rated assembly for on-road duty.
Heavy-Duty IndustrialHigh-current busbars and reinforced MOSFET bank for repeated peak loads.

JK BMS 2A+ Model Matrix

B2A (2A) and relay B5A (5A) high-current balancing tiers.

View specifications
ModelBalance CurrentContinuous CurrentLiFePO4 StringsLTO StringsControl PortCurrent SensingOCP Adjustable
B2A 20S20P2 A200 A8S–20S12S–20SCommon Port—10–200 A
B2A25S-RP (Relay)2 AUp to 600 A6S–25S9S–25S12V Relay split portShunt 500 A 75mV10–500 A
B2A25S-XP (Relay)2 AUp to 600 A6S–25S9S–25S12V Relay split portShunt 500 A 75mV10–500 A
B5A4S-XP (Relay, 12V Battery)5 AUp to 600 A4S—12V Relay split portShunt 500 A 75mV10–500 A
B5A8S-XP (Relay, 24V Battery)5 AUp to 600 A8S—24V Relay split portShunt 500 A 75mV10–500 A

Engineering Guidance (Traction Pack)

Architecture decisions

View specifications
Design itemWhy it matters
Series count and pack voltageMust match motor controller input range and BMS threshold configuration.
Busbar and cabling gaugeIncorrect gauge creates voltage drop and thermal risk at 600 A continuous.
Mechanical mounting & vibration isolationProtects BMS board and connections in high-vibration traction environments.

Choosing the Balance Tier for Traction

View specifications
TierBalance CurrentWhen to choose
B2A (2A)2 A active balance
B5A Relay (5A)5 A active balance

Engineering Data

Specification Snapshot

Procurement-friendly parameters for fast vendor qualification. Request the PDF datasheet for electrical curves and compliance documents.

SKU

HC-BMS-600

Voltage Range

8S–24S (25.6–76.8 V)

Continuous Current

600 A

Peak Surge

1800 A (3s)

Active Balancing

2 A

Communication

CAN / RS485 / BT

Operating Temp

-20 °C to 70 °C

Cell Type

LiFePO4

Protection Class

IP65 (Enclosed)

Power Supply

30–100 V DC

Voltage Accuracy

±5 mV

OCP Range

10–500 A

Standby Draw

≤ 1 W active / 0.2 mW powered off

Safety Layer

BMS & Safety

Protection and compliance engineered to prevent the failures that trigger warranty claims, logistics delays, and downtime in traction applications.

Overcharge Protection

Per-cell voltage ceiling enforcement with balancing activation.

Over-discharge Cutoff

Programmable low-voltage disconnect prevents cell damage under deep discharge.

Short Circuit Protection

<200 µs response time for load-side faults.

Overcurrent Protection

Programmable threshold with dual time-window response; current-limit strategy absorbs motor inrush without nuisance trips.

Thermal Protection

NTC monitoring with programmable derating curve; MOSFET bank protected under sustained 600 A load.

Low-temp Charge Protection

Blocks charge below 0 °C to prevent cell damage.

CAN Fault Reporting

Real-time fault codes via CAN bus to the traction controller.

Cell Open-wire Detection

Identifies sense wire faults before cell imbalance occurs.

Compliance (CE, RoHS)

CE and RoHS documentation standard; UKCA and UL-recognized components aligned on request. Poland Local Warehouse 3–7 day DDP for qualified EU programs.

Control Integration

Motor Controller / Charger Communication

Motion batteries talk to the motor controller, not a grid inverter. CAN 2.0B (J1939-compatible) and RS485 map SOC, voltage, current, temperature, and fault status to the vehicle ECU or fleet EMS. Share your controller model and we align the protocol before sampling.

CAN 2.0B (J1939-compatible)
Primary interface for forklift, AGV, aerial-work-platform, and LSEV traction motor controllers and vehicle ECUs.
RS485 (Modbus RTU)
Telemetry and diagnostics for fleet management systems and telematics gateways.
Bluetooth 5.0
Local configuration and cell-level monitoring via the SSLBATT mobile app in the workshop.
Charge-Port / Opportunity Charging
CAN handshake with opportunity and fast chargers so charging is gated by the BMS, not the charger alone.
Custom CAN Mapping
Factory parameter alignment to your motor controller profile before sampling. Custom CAN J1939 PGN mapping available for OEM programs.
Fleet Telemetry
SOC, voltage, current, temperature, and fault codes forwarded to the fleet EMS for predictive maintenance.

Visual Context

Engineering Visuals

SSL High-Current BMS for Traction Applications | SSLBATT product visual
SSL High-Current BMS production and QA visual
SSL high-current BMS powering a forklift battery in a cold-storage warehouse

Where It Wins

Applications

Match this SKU to proven deployment contexts.

Browse Solutions

Forklift Fleets

Sustained 600 A for lift motors and fast-charge cycles.

AGV & Mobile Robotics

CAN-integrated BMS for automated vehicle fleets.

EV Traction & LSEV

Motor inrush-rated with vibration-tolerant packaging.

Heavy Industrial

Reinforced busbars for repeated peak load demand.

FAQ

Frequently Asked Questions

What cell configuration and voltage range does this BMS support?

8S to 24S LiFePO4, corresponding to 25.6 V to 76.8 V nominal. Confirm your pack series count and we align BMS parameters during the engineering fit check.

Can this BMS handle peak motor inrush currents?

Yes. Rated for 600 A continuous with 1800 A peak surge for up to 3 seconds, designed for motor inrush events in forklift, AGV, and electric vehicle traction drives.

Which communication protocols are supported?

CAN 2.0B (J1939-compatible), RS485 (Modbus RTU), and Bluetooth 5.0. CAN is the primary interface for traction motor controllers and vehicle ECUs.

What is the lead time and MOQ?

Standard lead time is 3–4 weeks after configuration lock; MOQ is 10 units. OEM programs with custom protocol mapping or enclosure adaptation may require adjusted terms.

Real Photos

Factory & Product Gallery

JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — product photo
JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — product photo
JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — close-up detail
JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — close-up detail
JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — application scenario
JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — application scenario
JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — production line
JK BMS 2A+ 600 A for Traction | Forklift, AGV, LSEV — production line

Request Quote

Request OEM Quote

Factory-direct pricing, MOQ details, and OEM/ODM timelines for the High-Current Series Traction BMS.